Reverse Osmosis Plant is widely used for removal of dissolve chemical impurities from brackish & seawater. Reverse osmosis is the process of forcing a solvent from a region of high dissolve solids concentration through a membrane to a region of low dissolve solids concentration by applying a pressure in excess of the osmotic pressure.The semi permeable membranes used for reverse osmosis have a dense polymer barrier layer in which separation takes place.
Biotic's RO Plants are designed for a variety of industrial & commercial applications requiring high quality equipment with a fast delivery and competitive price. These pre-engineered, pre-assembled and factory tested units minimize installation and start-up time. With simple utility connections and easy to set up controls, the unit is ready for quick on-line service. The control system is an advanced microprocessor based system that is very easy to use.
Biotic's RO Plants are available in flowrates from 0.25 M3/hr. to 100 M3/hr. Using high quality 4 and 8 inch semipermeable membrane and equipment’s for variety of applications.
Working PrincipalReverse osmosis is water purification process in which pre-treated & filtered water is connected to the high-pressure pump where pressure is developed and fed to the RO membranes.Reverse Osmosis membranes work on the Cross flow Filtration method where the salts get rejected partially and deliver pure water. Purified water is referred to as product and waste water is referred to as concentrate or reject. The percent of water delivered as product is called the recovery. The ratio of recovery& output parameters depend upon the feed water quality, type of membrane, temperature and total RO unit design considerations.
Approx. Rs 1.5 Lakh / UnitGet Latest Price
Product Details:Minimum Order Quantity | 1 Unit |
Brand | BWSPL |
Design | Customized, Standard |
Automatic Grade | Automatic, Semi-Automatic |
RO Capacity (Liter/hour) | 2000 LPH |
Brand/Make | BIOTIC WATER SOLUTIONS PVT. LTD. |
Number of Membranes in RO | 2 |
Max Water Recovery Rate | 75 % |
Voltage | 415 V AC |
Frequency | 50 Hz |
Installation Type | Complete Civil work with Installation |
High pressure pump | 2000 LPH |
Power Consumption (in kw) | 3.0 kw |
Phase | 3 |
ITEM | UNIT | 2000 LPH |
| ||
Feed TDS (max limit) | ppm | 5000 |
Product TDS | ppm | < 100 |
Feed Pump | Yes | |
Dual Media (Sand Carbon) Filter | Yes | |
Anti sScalant Dosing system | Yes | |
De Chlorination System | Optional | |
Micron Cartridge Filter | 5 micron | |
UV System | Optional | |
|
Approx. Rs 1.1 Lakh / Unit(s)Get Latest Price
Product Details:RO Capacity (Liter/hour) | 500-1000, 1000-2000 (Liter/hour), 200-500 (Liter/hour), 0-200 (Liter/hour), >3000, 2000-3000 (Liter/hour) |
Material | FRP |
Automation Grade | Automatic |
Installation/Civil Work | Available |
Max Water Recovery Rate | 65-70 %, 50-55 %, 60-65 %, 70-75 %, >75 %, 55-60 % |
Purification Type | RO |
Brand | BWSPL |
We are pioneers in offering a durable range of Commercial Commercial Reverse Osmosis System to the valued patrons. These offered RO systems are manufactured in compliance with the industry laid parameters that makes our range a credible choice from the patrons end. In addition to this, offered systems are easily installed at the patrons end by our team of skilled team mates who are well versed with the ongoing market demands. Besides, this range can be availed in various sizes and other detailed specifications from us.
Other details:
In the reverse osmosis process, cellophane like membranes separate purified water from contaminated water
Pressure is applied to the concentrated side of the membrane
It forces purified water into the dilute side while rejecting the impurities from the concentrated side being washed away in the reject water
RO can also act as an ultra-filter removing particles such as some micro-organisms that may be too large to pass through the pores of membrane
Approx. Rs 1.4 Lakh / UnitGet Latest Price
Product Details:Minimum Order Quantity | 1 Unit |
Brand | BWSPL |
Plant Application | Domestic RO Plant |
Automatic Grade | Automatic |
RO Capacity (Liter/hour) | 200-500 (Liter/hour), 1000-2000 (Liter/hour), 2000-3000 (Liter/hour), 500-1000, >3000, 0-200 (Liter/hour) |
Number of Membranes in RO | 1 |
Material of Construction | FRP |
Plant Accessories | Chlorinator |
Installation Type | Complete Civil work with Installation |
Reverse Osmosis Plant is widely used for removal of dissolve chemical impurities from brackish & seawater. Reverse osmosis is the process of forcing a solvent from a region of high dissolve solids concentration through a membrane to a region of low dissolve solids concentration by applying a pressure in excess of the osmotic pressure.The semi-permeable membranes used for reverse osmosis have a dense polymer barrier layer in which separation takes place.
RO Plants are designed for a variety of industrial & commercial applications requiring high-quality equipment with a fast delivery and competitive price. These pre-engineered, pre-assembled and factory tested units minimize installation and start-up time. With simple utility connections and easy to set up controls, the unit is ready for quick on-line service. The control system is an advanced microprocessor-based system that is very easy to use.
RO Plants are available in flowrates from 0.25 M3/hr. to 100 M3/hr. Using high quality 4 and 8 inch semipermeable membrane and equipment’s for variety of applications.
Working Principal
Reverse osmosis is water purification process in which pre-treated & filtered water is connected to the high-pressure pump where pressure is developed and fed to the RO membranes.Reverse Osmosis membranes work on the Cross flow Filtration method where the salts get rejected partially and deliver pure water. Purified water is referred to as product and waste water is referred to as concentrate or reject. The percent of water delivered as product is called the recovery. The ratio of recovery& output parameters depend upon the feed water quality, type of membrane, temperature and total RO unit design considerations.
Approx. Rs 75,000 / UnitGet Latest Price
Product Details:Minimum Order Quantity | 1 Unit |
Plant Application | Industrial RO Plant, Domestic RO Plant, Institutional RO Plant |
RO Capacity (Liter/hour) | 500 LPH |
Number of Membranes in RO | 4 |
Automation Grade | Automatic |
Voltage | 415 V AC |
Max Water Recovery Rate | 40 % |
Number of Filtration Passes | 5 |
Frequency | 50 Hz |
High pressure pump | 1550 LPH |
Phase | 3 |
Reverse osmosis plants(RO Plant) require a variety of pre-treatment techniques and high pressure to remove impurities. A semipermeable membrane blocks contaminants from entering the treated water, while allowing purified water to pass through.
Reverse osmosis plants(RO Plant) are water desalination plants that use reverse osmosis to purify water. The process of RO Plant takes place in reverse osmosis plants, where contaminated water is forced through a membrane to produce pure water. RO Plant also produces salty brine waste during the process.
ITEM | UNIT | 500 LPH |
| ||
Feed TDS (max limit) | ppm | 5000 |
Product TDS | ppm | < 100 |
Feed Pump |
| Yes |
Dual Media (Sand Carbon) Filter |
| Yes |
Anti sScalant Dosing system |
| Yes |
De Chlorination System |
| Optional |
Micron Cartridge Filter |
| 5 micron |
|
|
|
Reverse Osmosis (RO) Membrane |
| FILMTEC TM RO INSIDE, 4” |
UV System |
| Optional |
Power Consumption | KW | 2.94 |
Dimension (wxdxh) | mm | 890x 890 x 1850 |
Automatic Grade | Semi-Automatic |
Approx. Rs 85,000 / UnitGet Latest Price
Product Details:Minimum Order Quantity | 1 Unit |
Plant Application | Industrial RO Plant, Domestic RO Plant, Institutional RO Plant |
Max Water Recovery Rate | 65-70 %, 70-75 % |
Plant Accessories | Chlorinator, Ozonator |
Design | Customized |
Material of Construction | Stainless Steel, FRP |
Types Of Machines | Reverse Osmosis Unit |
Installation/Civil Work | Not Required |
RO Capacity (Liter/hour) | 1000 LPH |
Operation Mode | Automatic |
Number Of Filtration Passes | 2 |
Number of Membranes in RO | 4 |
Automation Grade | Automatic |
Voltage | 415 V AC |
Frequency | 50 Hz |
Input Voltage | 240 |
Motor Power | 3 kw |
High pressure pump | 3000 LPH |
Power Consumption (in kw) | 4.95 kw |
Chiller Cooling Capacity (Tons) | 2 ton |
Installation Type | Containerized Plug & Play |
Storage Tank | 2000 Lits |
Application | Drinking Water |
Tds Rejection | 98-99% |
Post Filtration | Micron Filter |
Use | Drinking Water |
Size Of Membrane | 4040 |
Electricity | 3 KW |
Phase | 3 |
Total Dissolved Solids | 3000 |
Capacity (litres per hour) | 1000-2000 Liter/hour |
Reverse Osmosis Systems Repair and Maintenance Required | No |
ITEM | UNIT | 1000 LPH |
| ||
Feed TDS (max limit) | ppm | 5000 |
Product TDS | ppm | < 100 |
Feed Pump |
| Yes |
Dual Media (Sand Carbon) Filter |
| Yes |
Anti sScalant Dosing system |
| Yes |
De Chlorination System |
| Optional |
Micron Cartridge Filter |
| 5 micron |
| ||
Reverse Osmosis (RO) Membrane |
| FILMTEC TM RO INSIDE, 4" |
UV System |
| Optional |
Dimension (wxdxh) | mm | 890x 890 x 1850 |
Additional Information:
Approx. Rs 65,000 / UnitGet Latest Price
Product Details:Minimum Order Quantity | 1 Unit |
Plant Application | Institutional RO Plant, Industrial RO Plant |
Automatic Grade | Automatic |
RO Capacity (Liter/hour) | 250 |
Number of Membranes in RO | 4 |
Max Water Recovery Rate | 28 % |
Number of Filtration Passes | 5 |
Voltage | 415 V |
Frequency | 50 Hz |
Phase | 3 |
Product Dimensions (L*B*H) | 590 x 590 x 1450 mm |
ITEM | UNIT | 250 LPH |
| ||
Feed TDS (max limit) | ppm | 5000 |
Product TDS | ppm | < 100 |
Feed Pump |
| Yes |
Dual Media (Sand Carbon) Filter |
| Yes |
Anti sScalant Dosing system |
| Yes |
De Chlorination System |
| Optional |
Micron Cartridge Filter |
| 5 micron |
High Pressure Pump (capacity) | LPH | 1320 |
Reverse Osmosis (RO) Membrane |
| FILMTEC TM RO INSIDE, 4” |
UV System |
| Optional |
Power Consumption | KW | 1.65 |
|
Approx. Rs 1.95 Lakh / UnitGet Latest Price
Product Details:Minimum Order Quantity | 1 Unit |
Design | Customized, Standard |
Automatic Grade | Automatic, Semi-Automatic |
RO Capacity (Liter/hour) | 1500 LPH |
Brand/Make | BIOTIC WATER SOLUTIONS PVT. LTD. |
Number of Membranes in RO | 6 |
Max Water Recovery Rate | 75 % |
Voltage | 415 V AC |
Frequency | 50 Hz |
High pressure pump | 2000 LPH |
Power Consumption (in kw) | 2.5 kw |
Phase | 3 |
ITEM | UNIT | 1500 LPH |
| ||
Feed TDS (max limit) | ppm | 5000 |
Product TDS | ppm | < 100 |
Feed Pump | Yes | |
Dual Media (Sand Carbon) Filter | Yes | |
Anti sScalant Dosing system | Yes | |
De Chlorination System | Optional | |
Micron Cartridge Filter | 5 micron | |
UV System | Optional | |
Approx. Rs 55,000 / PieceGet Latest Price
Product Details:Minimum Order Quantity | 1 Piece |
Plant Application | Industrial RO Plant, Domestic RO Plant, Institutional RO Plant |
Installation/Civil Work | Required |
Automatic Grade | Automatic |
RO Capacity (Liter/hour) | 500-1000, 1000-2000 (Liter/hour), 0-200 (Liter/hour), 2000-3000 (Liter/hour), 200-500 (Liter/hour), >3000 |
Chiller Cooling Capacity (Tons) | 0.5 ton |
Brand/Make | BWSPL |
Number of Membranes in RO | 2 |
Material of Construction | FRP |
Reverse Osmosis Plant is widely used for removal of dissolve chemical impurities from brackish & seawater. Reverse osmosis is the process of forcing a solvent from a region of high dissolve solids concentration through a membrane to a region of low dissolve solids concentration by applying a pressure in excess of the osmotic pressure.The semi permeable membranes used for reverse osmosis have a dense polymer barrier layer in which separation takes place.
RO Plants are designed for a variety of industrial & commercial applications requiring high quality equipment with a fast delivery and competitive price. These pre-engineered, pre-assembled and factory tested units minimize installation and start-up time. With simple utility connections and easy to set up controls, the unit is ready for quick on-line service. The control system is an advanced microprocessor based system that is very easy to use.
RO Plants are available in flowrates from 0.25 M3/hr. to 100 M3/hr. Using high quality 4 and 8 inch semipermeable membrane and equipment’s for variety of applications.
Working Principal
Reverse osmosis is water purification process in which pre-treated & filtered water is connected to the high-pressure pump where pressure is developed and fed to the RO membranes.Reverse Osmosis membranes work on the Cross flow Filtration method where the salts get rejected partially and deliver pure water. Purified water is referred to as product and waste water is referred to as concentrate or reject. The percent of water delivered as product is called the recovery. The ratio of recovery& output parameters depend upon the feed water quality, type of membrane, temperature and total RO unit design considerations.
Explore More Products
Reviewed by 12 Users
Most Relevant Reviews
© Biotic Water Solutions Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited